F / Sets
Metabolic Set
Metabolic Set is two vials supplied as one package. Each vial inside it is filled, tested and released under its own lot number.
- 02Vials
- Set of vialsPresentation
- As each vialStorage

The turn
This set was not shot on the turntable. Each vial inside it has its own turn on its own page.
Turn the vials
The vials of the set as they are made, each with its own printed label.

Technical sheet
What the product is, stated as identifiers. Lot values are on the certificate and nowhere else.
| Product | Metabolic Set | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Vials in the set | Two vials | |||||||||
| Presentation | Set of vials | |||||||||
| Kind | Set of sealed vials | |||||||||
| Contents |
| |||||||||
| Storage | As each vial | |||||||||
| Use | Research use only. Not for human consumption. | |||||||||
| Lot format | LYT-0000-X Format shown. Not a lot in supply. Each vial in the set carries its own lot number in this format. | |||||||||
| Certificate | Look up a lot The certificate for a lot opens from the lookup once it is published. |
How this lot was made
Five steps behind every vial in this set, each with its control and its record.
- 01
Synthesis
Sequences are assembled by solid-phase peptide synthesis, residue by residue.
Step 01 on the process page - 02
Purification
Crude peptide is purified by preparative HPLC. Fractions are pooled against the purity specification.
Step 02 on the process page - 03
- 04
Fill and finish
Vials are filled by mass, stoppered and crimp-sealed with an aluminium cap.
Step 04 on the process page - 05
Release testing
Each lot is tested for HPLC purity and pH, then released with its certificate.
Step 05 on the process page
Schematic. No lot values are shown.

Released by lot, with its certificate
A lot of this product is not supplied until it is tested. Release is a decision against a written specification, taken once per lot.
- The lot is tested for purity by HPLC and for pH.
- Results are compared against the specification, not against the previous lot.
- A lot that does not meet the specification is not released.
Each lot is released against a written purity specification. The result for a lot is on its certificate.
Purity is confirmed by an independent third-party laboratory alongside our own release testing.
Look up a lot of Metabolic Set
Enter the lot number printed on the Metabolic Set label.Accepted format LYT-0000-X
Further lot documentation is available to distributors and research organisations on request.
Also in group F
Sets. The other products indexed beside this one.
Enquiries